{"id":926,"date":"2026-07-13T06:45:10","date_gmt":"2026-07-13T06:45:10","guid":{"rendered":"https:\/\/nursenexusjournal.com\/?page_id=926"},"modified":"2026-07-13T06:48:25","modified_gmt":"2026-07-13T06:48:25","slug":"sigurnost-osoblja-i-pacijenata-kod-magnetske-rezonancije","status":"publish","type":"page","link":"https:\/\/nursenexusjournal.com\/en\/volume-1-issue-1\/sigurnost-osoblja-i-pacijenata-kod-magnetske-rezonancije\/","title":{"rendered":"SIGURNOST OSOBLJA I PACIJENATA KOD MAGNETSKE REZONANCIJE"},"content":{"rendered":"<div class=\"et_pb_section_0 et_pb_section et_section_regular et_flex_section\">\n<div class=\"et_pb_row_0 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_0 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_code_0 et_pb_code et_pb_module\"><div class=\"et_pb_code_inner\"><style>\n.nnj-article-page{\n    max-width:900px;\n    margin:60px auto;\n    padding:0 20px;\n    font-family:inherit;\n    color:#1d2b3a;\n}\n\n.nnj-breadcrumb{\n    font-size:14px;\n    color:#6b7a8b;\n    margin-bottom:18px;\n}\n\n.nnj-breadcrumb a{\n    color:#2289b8;\n    text-decoration:none;\n}\n\n.nnj-card{\n    background:#fff;\n    border:1px solid #e5edf5;\n    border-radius:22px;\n    padding:40px;\n    box-shadow:0 18px 40px rgba(18,35,60,.08);\n}\n\n.nnj-title{\n    font-size:36px;\n    line-height:1.25;\n    margin:0 0 20px;\n    color:#112845;\n}\n\n.nnj-authors{\n    font-size:18px;\n    color:#4c6176;\n    margin-bottom:30px;\n    line-height:1.7;\n}\n\n.nnj-meta{\n    display:grid;\n    grid-template-columns:170px 1fr;\n    gap:14px 22px;\n    margin-bottom:35px;\n    padding:25px;\n    background:#f8fbfd;\n    border:1px solid #e3edf4;\n    border-radius:18px;\n}\n\n.nnj-meta strong{\n    color:#10243f;\n}\n\n.nnj-meta a{\n    color:#2289b8;\n    text-decoration:none;\n    word-break:break-all;\n}\n\n.nnj-download{\n    display:inline-block;\n    margin-top:8px;\n    padding:13px 24px;\n    background:#238db6;\n    color:#fff !important;\n    text-decoration:none;\n    border-radius:10px;\n    font-weight:700;\n    transition:.2s;\n}\n\n.nnj-download:hover{\n    background:#197aa1;\n}\n\n.nnj-section{\n    margin-top:40px;\n}\n\n.nnj-section h2{\n    margin:0 0 16px;\n    font-size:26px;\n    color:#10243f;\n}\n\n.nnj-section p{\n    margin:0;\n    font-size:16px;\n    line-height:1.85;\n    color:#47596b;\n}\n\n@media(max-width:768px){\n\n.nnj-card{\n    padding:28px;\n}\n\n.nnj-title{\n    font-size:28px;\n}\n\n.nnj-meta{\n    grid-template-columns:1fr;\n}\n\n}\n  .author-num{\n    position: relative;\n    top: -0.35em;\n    font-size: 70%;\n    margin-left: 2px;\n}\n<\/style>\n\n<div class=\"nnj-article-page\">\n\n<div class=\"nnj-breadcrumb\">\n<a href=\"\/\">Home<\/a> \/\n<a href=\"\/volume-1-issue-1\/\">Volume 1, Issue 1<\/a>\n<\/div>\n\n<div class=\"nnj-card\">\n\n<h1 class=\"nnj-title\">\nSAFETY OF STAFF AND PATIENTS IN\nMAGNETIC RESONANCE IMAGING\n<\/h1>\n\n<div class=\"nnj-authors\">\nRisti\u0107 Sini\u0161a<span class=\"author-num\">1<\/span>\n<\/div>\n\n<div class=\"nnj-meta\">\n\n<strong>Volumes<\/strong>\n<div>Volume 1, Issue 1 (2026)<\/div>\n\n<strong>DOI<\/strong>\n<div>10.xxxx\/xxxxx.xxxxx<\/div>\n\n<strong>Keywords<\/strong>\n<div>computed tomography, magnetic\nresonance, patient safety.<\/div>\n\n<strong>PDF Document<\/strong>\n<div>\n<a class=\"nnj-download\"\nhref=\"https:\/\/nursenexusjournal.com\/wp-content\/uploads\/2026\/07\/SAFETY-OF-STAFF-AND-PATIENTS-IN-MAGNETIC-RESONANCE-IMAGING.pdf\"\ntarget=\"_blank\">\nDownload PDF\n<\/a>\n<\/div>\n\n<\/div>\n\n<div class=\"nnj-section\">\n\n<h2>ABSTRACT<\/h2>\n\n<p>\n\nIntroduction. Magnetic resonance imaging (MRI) is\none of the most important diagnostic methods in\nmodern medicine due to its superior visualization of\nsoft tissues and the absence of ionizing radiation. MRI\ntechnology is based on the action of a strong static\nmagnetic field, radiofrequency pulses, and gradient\nfields, enabling high-quality imaging while\nsimultaneously presenting significant safety risks.<br> <br>\nThe\naim of this paper was to present the basic physical\nprinciples of MRI, compare MRI and CT through their\nadvantages and disadvantages, and provide a detailed\nanalysis of safety procedures, risks, and protective\nmeasures for patients and healthcare staff. The paper\ndescribes the main hazards associated with MRI\nexaminations, including the projectile effect, tissue\nheating, burns, noise exposure, claustrophobia, risks\nrelated to implants, and the use of gadolinium-based\ncontrast agents. Special attention is given to implant\nsafety and differences in risks between 1.5 T, 3 T, and\n7 T systems. MRI safety zones, the importance of\ndetailed patient screening, access control to the MRI\nsuite, and the use of MRI-compatible equipment are\n\nalso analyzed.<br><br>The findings indicate that most MRI-\nrelated incidents result from human error, inadequate\n\nscreening, or insufficient staff education. The greatest\nrisks are associated with ferromagnetic objects,  unverified implants, and failure to follow safety\nprotocols. As magnetic field strength increases, the\nrisks of projectile accidents, tissue heating, peripheral\nnerve stimulation, and hearing damage also increase.\n  \n  <br><br>Conclusion. MRI is an extremely valuable but\npotentially hazardous diagnostic method if safety\nprotocols are not consistently implemented.\nContinuous staff education, strict adherence to safety\nprocedures, and proper patient assessment are essential\nprerequisites for safe work in the MRI environment.\n\n<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div><\/div><\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":884,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-926","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/pages\/926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/comments?post=926"}],"version-history":[{"count":4,"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/pages\/926\/revisions"}],"predecessor-version":[{"id":930,"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/pages\/926\/revisions\/930"}],"up":[{"embeddable":true,"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/pages\/884"}],"wp:attachment":[{"href":"https:\/\/nursenexusjournal.com\/en\/wp-json\/wp\/v2\/media?parent=926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}